Accelerated bearing life-Time test rig development for low speed data acquisition
2017
Condition monitoring plays an important role in rotating machinery to ensure reliability of the equipment, and to detect fault conditions at an early stage. Although health monitoring methodologies have been thoroughly developed for rotating machinery, low-speed conditions often pose a challenge due to the low signal-to-noise ratio. To this aim, sophisticated algorithms that reduce noise and highlight the bearing faults are necessary to accurately diagnose machines undergoing this condition. In the development phase, sensor data from a healthy and damaged bearing rotating at low-speed is required to verify the performance of such algorithms. A test rig for performing accelerated life-time t…
Characterization of DC series arc faults in PV systems based on current low frequency spectral analysis
2021
Abstract This work presents an experimental study focused on the characterization of series arc faults in direct current (DC) photovoltaic (PV) systems. The aim of the study is to identify some relevant characteristics of arcing current, which can be obtained by means of low frequency spectral analysis of current signal. On field tests have been carried out on a real PV system, in accordance with some tests requirements of UL 1699B Standard for protection devices against PV DC arc faults. Arcing and non-arcing current signals are acquired and compared and the behavior of a set of indicators proposed by authors is analyzed. Different measurement equipment have been used, in order to study th…
Validation of a New Method for the Diagnosis of Rotor bar Failures via Wavelet Transformation in Industrial Induction Machines
2006
[EN] In this paper, the authors propose a method for the diagnosis of rotor bar failures in induction machines, based on the analysis of the stator current during the startup using the discrete wavelet transform (DWT). Unlike other approaches, the study of the high-order wavelet signals resulting from the decomposition is the core of the proposed method. After an introduction of the physical and mathematical bases of the method, a description of the proposed approach is given; for this purpose, a numerical model of induction machine is used in such a way that the effects of a bar breakage can clearly be shown, avoiding the influence of other phenomena not related with the fault. Afterward, …
The Use of the Wavelet Approximation Signal as a Tool for the Diagnosis of Rotor Bar Failures
2005
[EN] The aim of this paper is to present a new approach for rotor bar failure diagnosis in induction machines. The method focuses on the study of an approximation signal resulting from the wavelet decomposition of the startup stator current. The presence of the left sideband harmonic is used as evidence of the rotor failure in most diagnosis methods based on the analysis of the stator current. Thus, a detailed description of the evolution of the left sideband harmonic during the startup transient is given in this paper; for this purpose, a method for calculating the evolution of the left sideband during the startup is developed, and its results are physically explained. This paper also show…
A set of indicators for arc faults detection based on low frequency harmonic analysis
2016
In this paper a novel set of indicators is presented for arc faults detection in electrical circuits. The indicators are defined starting from an experimental characterization of the arc fault phenomenon and the study of the arcing current in several test conditions, which were chosen in accordance with the UL 1699 Standard requirements. The proposed parameters are measured by means of a high resolution low frequency spectral analysis of the arcing current, which allows to achieve a good spectral resolution even with short observation windows.
Broken rotor bars detection via Park's vector approach based on ANFIS
2014
Many attempts have been made on fault diagnosis of induction motors based on frequency and time domain analysis of stator current. In this paper, first the Park's vector transformation and frequency analysis for fault detection of induction motors are introduced. Then a smart approach using Adaptive Neuro Fuzzy Inference System (ANFIS) is proposed. This approach uses the time domain features derived from the Park's vector transformation of stator current. By the proposed method, a partial break including 5 mm crack on a bar, one broken bar and two broken bars using experimental data are investigated. It will be shown that features derived from Park's vector compared to features obtained fro…
Rotor-bar breakage mechanism and prognosis in an induction motor
2015
© 1982-2012 IEEE. This paper proposes a condition-based maintenance and prognostics and health management (CBM/PHM) procedure for a rotor bar in an induction motor. The methodology is based on the results of a fatigue test intended to reproduce in the most natural way a bar breakage in order to carry out a comparison between transient and stationary diagnosis methods for incipient fault detection. Newly developed techniques in stator-current transient analysis have allowed tracking the developing fault during the last part of the test, identifying the failure mechanism, and establishing a physical model of the process. This nonlinear failure model is integrated in a particle filtering algor…
Vibration signature analysis for rotor broken bar diagnosis in double cage induction motor drives
2013
The paper investigates the diagnosis of rotor broken bars in field oriented controlled (FOC) double cage induction motor drives, using current and vibration signature analysis techniques. The Impact of the closed loop control system cannot be neglected when the detection of asymmetries in the machine are based on the signature analysis of electrical variables. The proposed diagnosis approach is based on optimized use of wavelet analysis by a pre-processing of phase current or axial/radial vibration signals. Thus, the time evolution of the tracked rotor fault components can be effectively analyzed. This paper shows also the relevance of the fault components computed from axial vibration sign…
Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis
2017
This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard…
Diagnosis of mechanical unbalance for double cage induction motor load in time-varying conditions based on motor vibration signature analysis
2013
This paper investigates the detectability of mechanical unbalance in double cage induction motor load using motor vibration signature analysis technique. Rotor imbalances induce specific harmonic components in electrical, electromagnetical, and mechanical quantities. Harmonic components characteristic of this category of rotor faults, issued from vibration signals analysis, are closely related to rotating speed of the rotor, which complicates its detection under non-stationary operating conditions of the motor. Firstly, experimental results were performed first under healthy and mechanical load unbalance cases, for different load levels under steady-state operating conditions to evaluate th…